##TITLE= Audit trail, TopSpin 4.4.0
##JCAMPDX= 5.01
##ORIGIN= Bruker BioSpin GmbH & Co. KG
##OWNER= andre
$$ C:/Working NMR Data/fruk-si381-sic-013-f/10/pdata/1/auditp.txt
##AUDIT TRAIL=  $$ (NUMBER, WHEN, WHO, WHERE, PROCESS, VERSION, WHAT)
(   1,<2024-08-12 13:34:06.436 +0100>,<Administrator>,<cragganmore>,<go4>,<TopSpin 3.6.4>,
      <created by zg on data set with UUID 'c65330ac-58a6-11ef-afce-000af70978bf'
       started at 2024-08-12 13:31:18.786 +0100,
       POWCHK enabled, PULCHK disabled,
       completed at 2024-08-12 13:34:06.420 +0100

       configuration hash MD5:
       BB 9B F4 58 43 B0 D2 7C D9 DA 30 C8 13 9F 28 AF
       data hash MD5: 256K
       53 84 4E B1 C1 C9 12 E0 07 A7 70 65 22 5C 23 7B
>)
(   2,<2024-08-12T13:44:42.034+0100>,<andre>,<AM_NMR_DELL>,<proc1d>,<TopSpin 4.4.0>,
      <Start of raw data processing
       efp LB = 0.3 FT_mod = 6 PKNL = 1 PHC0 = 0 PHC1 = 0 SI = 256K 
       data hash MD5: 256K
       CE 25 13 F3 BB 8C 4B 30 93 1E 77 81 14 E0 AF 4B>)
(   3,<2024-08-12T13:45:00.960+0100>,<andre>,<AM_NMR_DELL>,<dataserver>,<TopSpin 4.4.0>,
      <apbk
       data hash MD5: 256K
       2E 98 FA 8C CE DB 70 AE DF BE B4 7B 2F EF C1 D4>)
(   4,<2024-08-12T13:45:01.629+0100>,<andre>,<AM_NMR_DELL>,<proc1d>,<TopSpin 4.4.0>,
      <ht 
       data hash MD5: 256K
       2E 98 FA 8C CE DB 70 AE DF BE B4 7B 2F EF C1 D4>)
(   5,<2024-08-12T13:45:16.588+0100>,<andre>,<AM_NMR_DELL>,<peak>,<TopSpin 4.4.0>,
      <1D Peak picking
       data hash MD5: 256K
       2E 98 FA 8C CE DB 70 AE DF BE B4 7B 2F EF C1 D4>)
(   6,<2024-08-12T13:45:25.290+0100>,<andre>,<AM_NMR_DELL>,<cprserver>,<TopSpin 4.4.0>,
      <changed parameter F1 CY to 200>)
(   7,<2024-08-12T13:45:25.513+0100>,<andre>,<AM_NMR_DELL>,<cprserver>,<TopSpin 4.4.0>,
      <changed parameter F1 MAXI to 22222.00>)
(   8,<2024-08-12T13:45:29.220+0100>,<andre>,<AM_NMR_DELL>,<cprserver>,<TopSpin 4.4.0>,
      <changed parameter F1 MI to 100>)
(   9,<2024-08-12T13:45:31.445+0100>,<andre>,<AM_NMR_DELL>,<peak>,<TopSpin 4.4.0>,
      <1D Peak picking
       data hash MD5: 256K
       2E 98 FA 8C CE DB 70 AE DF BE B4 7B 2F EF C1 D4>)
(  10,<2024-08-12T13:47:27.821+0100>,<andre>,<AM_NMR_DELL>,<dataserver>,<TopSpin 4.4.0>,
      <Start of interactive peak picking
       data hash MD5: 256K
       2E 98 FA 8C CE DB 70 AE DF BE B4 7B 2F EF C1 D4>)
(  11,<2024-08-12T13:47:37.858+0100>,<andre>,<AM_NMR_DELL>,<dataserver>,<TopSpin 4.4.0>,
      <Peak added manually at position -146.2647
       data hash MD5: 256K
       2E 98 FA 8C CE DB 70 AE DF BE B4 7B 2F EF C1 D4>)
(  12,<2024-08-12T13:47:37.883+0100>,<andre>,<AM_NMR_DELL>,<dataserver>,<TopSpin 4.4.0>,
      <End of interactive peak picking
       data hash MD5: 256K
       2E 98 FA 8C CE DB 70 AE DF BE B4 7B 2F EF C1 D4>)
(  13,<2024-08-12T13:48:23.132+0100>,<andre>,<AM_NMR_DELL>,<disknew>,<TopSpin 4.4.0>,
      <processed data deleted by delp>)
##END=

$$ hash MD5
$$ 53 16 87 E0 08 2F F6 04 A2 7C 8E C4 BA F7 A5 74